Errors reported with Release 20.1 |
|---|
***********************************************************************;
* (C) COPYRIGHT 2010, COMPUTER MANAGEMENT SCIENCES, INC. ;
* ALL RIGHTS RESERVED. ;
***********************************************************************;
This member contains a log of the errors which were discovered with
CPExpert Release 20.1, and acknowledges the user who discovered the
error. Thanks for reporting the errors!
DATE MODULE ERROR DESCRIPTION
05/05/10 WLMEVALF Corrected test for SAS/ITRM PDB. Bad test caused improper
seetting of OBS64, which caused error if PDB did not have the
TYPE64 file.
Don Williams (UNC Hospitals, NC)
05/07/10 WLMPRSML Revised shared processor information to show total
physical processors by processor type that were
shared, and added information for total logical
processors, by processor type.
Don Williams (UNC Hospitals, NC)
05/11/10 WLMDEFLT Corrected CHKSMF (default should have been N).
Glenn Bowman (Wakefern Food Corp,, NJ)
05/11/10 WLM030U4 Corrected macro variable OBS304 to OBS30_4.
Don Williams (UNC Hospitals, NC)
06/23/10 DB2GUIDE Corrected %LET BP_DESCRIPTION=N; to be %LET BP_DES=N;
in USOURCE(DB2GUIDE).
Thomas Grocke and Harald Seifert (HUK-Coberg, Germany)
06/23/10 WLM71S Added test for SAS/ITRM before executing %sysfunct test for
presence of the TYPE71 file in the MXG pdb.
Thomas Grocke and Harald Seifert (HUK-Coberg, Germany)
6/26/10 DASEVAL1 Added FORMAT for &SMF74RMF and &SMF74INT to accommodate
SAS/ITRM uniqueue values in Germany.
Thomas Grocke and Harald Seifert (HUK-Coburg, Germany)
6/26/10 WLMEVAL1 Specify FORMAT TIME12.2 for &SMF72int to avoid SAS WARNING
WLMEVAL2 when using CPExpert with SAS/ITRM.
WLMEVAL3 Thomas Grocke and Harald Seifert (HUK-Coburg, Germany)
WLMEVALF
WLMEVALI
WLMEVALJ
WLMEVALL
WLMEVALP
WLMEVALQ
WLMEVALS
6/29/10 WLMEVALC Establish logic to handle case where specific system(s)
and times were selected and suppress findings from TYPE74SY
outside system(s) and times, but findings were made for some
interval for the selected data.
Thomas Grocke and Harald Seifert (HUK-Coburg, Germany)
6/29/10 CICMXG4 Added logic to identify more CICS files that have APPLIDs
that are not in the CICS Dispatcher Statistics file.
Thomas Grocke and Harald Seifert (HUK-Coburg, Germany)
6/30/10 WMQEVAL Added HOUR computation based on WMQLOG data.
Thomas Grocke and Harald Seifert (HUK-Coburg, Germany)
07/01/10 CIC145 Shortened Line 23 to prevent column 72 overrun (a problem
WLM095 when a site has SAS option S2=value).
Wayne Hammond (Bank of America, GA).
07/01/10 WLMEVALQ Added GENSELTM and associated code to allow normal selection.
Thomas Grocke and Harald Seifert (HUK-Coburg, Germany)
07/02/10 WLMLIST Add %LET RULECAT=%TRIM(&RULECAT) to allow correct comparisons,
and reorder logic for setting RULECAT.
Rick Ralston (HUMANA, KY)
07/02/10 WLMEVALC Establish logic to handle case where specific system(s)
and times were selected and suppress findings from TYPE74SY
outside system(s) and times, but findings were made for some
interval for the selected data.
Harald Seifert (HUK-Coburg, Germany)
07/05/10 DASCONFG Added test for shared devices at EOF74.
Harald Seifert (HUK-Coburg, Germany)
07/13/10 WLMEVALF Corrected %END location to be after CALL SYMPUT.
Wayne Hammond (Bank of America, GA).
07/14/10 WLMEVALP Establish number local page data sets as a macro variable,
since the old maximum of 50 local page data sets was too
small (sites now have more than 50 local page data sets per
system).
Wayne Hammond (Bank of America, GA).
07/28/10 WLMEVALI Revise logic for "dummy" control variables to yield proper
sort order in ODS html rule categories.
Rick Ralston (HUMANA, KY)
08/18/10 WLMEVALC Compute TOTALMSG which was computed in WLM601 (now suppressed)
Rick Ralston (HUMANA, KY)
08/25/10 WLMMPLR Added SAS ODS code.
WLMCPUR Rick Ralston (HUMANA, KY)
08/25/10 WLMRPTQ Increased LINECT value.
Rick Ralston (HUMANA, KY)
09/14/10 WLMEVALQ Corrected ENQ30_4 = OBS30_4.
Ahmet Alper Tecimer (Garanti Teknoloj, Turkey)
10/10/10 WLM094 Corrected OUTWLM macro parameter in continuation rules.
Ahmet Alper Tecimer (Garanti Teknoloj, Turkey)
10/12/10 GENLOG Moved "dummy system" code to after GENSELTM selection tests,
otherwise logger analysis would not be done when specific
systems were selected for analysis.
Ahmet Alper Tecimer (Garanti Teknoloj, Turkey)
|
Read errors with the previous release of CPExpert
Return to main page
Last updated by Don Deese on 10/12/10.